Logo
Occupancy Classification Search Engine is a cross-reference database, which classifies a building structure or part thereof into a group based on the specific purpose for which it is designed or occupied.  Our intelligent backbone technology empowers you to operate in a more efficient level and assist you in determining the appropriate occupancy classification.
SEARCH BY THE BUILDING USAGE FIRST CHARACTER
| A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 
 
SEARCH BY OCCUPANCY GROUP
| A-1 | A-2 | A-3 | A-4 | A-5 | B | E | F-1 | F-2 | H-1 | H-2 | H-3 | H-4 | H-5 | Group I | I-3 | M | Group R | R-1 | R-2 | R-3 | S-1 | S-2 | U
 
Type the Building Usage:
 
 
Occupancy Usage Classification
1 Class 3 Nondetonable Unstable (reactive) materials   H-2 Details  
 
2 Class3 nondetonable Water-reactive materials   H-2 Details  
 
3 Combination flammable liquid (1A, 1B, 1C)   H-2 Details  
 
4 Combustible dusts   H-2 Details  
 
5 Combustible dusts where manufactured, generated or used   H-2 Details  
 
6 Combustible dusts where manufactured, generated or used in such a manner that the concentration and conditions create a fire or explosion hazard based on information prepared in accordance with Section 414.1.3   H-2 Details  
 
7 Combustible or flammable liquid (Class I)   H-2 Details  
 
8 Combustible or flammable liquid (Class II)   H-2 Details  
 
9 Combustible or flammable liquid (Class IIIA)   H-2 Details  
 
10 Crude Peroxides, Class I Facilities   H-2 Details  
 
11 Cryogenic flammable   H-2 Details  
 
12 Cryogenic fluids   H-2 Details  
 
13 Cryogenic liquids, flammable   H-2 Details  
 
14 Flammable gases   H-2 Details  
 
15 Macrobiotic Peroxides, Class I Facilities   H-2 Details  
 
16 More than 15 lb per inche oxidizers Class3, used in closed containers   H-2 Details  
 
17 More than 15 lb per inche oxidizers Class3, used in closed systems   H-2 Details  
 
18 More than 15 lb per inche oxidizers Class3, used in open containers   H-2 Details  
 
19 More than 15 lb per inche oxidizers Class3, used in open systems   H-2 Details  
 
20 Natural Peroxides, Class I Facilities   H-2 Details  
 
21 Organic peroxides, Class I   H-2 Details  
 
22 Power Plant   H-2 Details  
 
23 Pyrophoric liquids, solids and gases, nondetonable   H-2 Details  
 
24 Solid Pyrophoric liquids, solids and gases   H-2 Details  
 
25 Systems pressurized at more than 15 pounds per sqare inches   H-2 Details  
 
26 Unrefined Peroxides, Class I Facilities   H-2 Details  
 
27 Unstable (reactive) materials, Class 3, nondetonable   H-2 Details  
 
28 Untreated Peroxides Facilities   H-2 Details  
 
29 Untreated Peroxides, Class I Facilities   H-2 Details  
 
30 Water-reactive materials, Class 3   H-2 Details  
 
© 2002- OptaSoft LLC. All rights reserved.